HPAOC2016-AG-001

Final Physical Air-Gap Test Plan — With AOC Monitor Clearances

EAM LLC | October 2026

Test Objective

Evaluate whether the HP EliteDesk 705 G4 Mini can display and operate the HPAOC2016 interface locally without an external network connection, while documenting the safety and condition of the original AOC e2343Fk monitor.

Two separate requirements must be evaluated: monitor electrical safety and workstation network isolation. Passing one does not establish the other. Neither constitutes security certification.

1. Hardware Inventory

ComponentTest role
AOC e2343FkHistorical display artifact
HP EliteDesk 705 G4 MiniOffline processing system
HP LV290AAHistorical input artifact
DisplayPort to DVI-DProposed video connection
Wired USB keyboard and mouseInitial controlled input
PatentSplitOutside the initial test scope

2. AOC Monitor Clearance

The original monitor shows visible corrosion in previously documented photographs. It must remain unpowered until a qualified electronics technician provides written electrical safety clearance.

STOP CONDITION: Do not energize the original monitor without professional clearance. Use a known-safe replacement display for computer-side testing.

Proposed ventilation clearances

Verify the installation requirements against the applicable AOC documentation before testing.

PositionClearance to verify
Above30 cm
Left10 cm
Right10 cm
Behind10 cm

3. Test Procedure

  1. Photograph and inventory the equipment.
  2. Obtain monitor clearance or select a safe substitute.
  3. Verify power adapters and video connections.
  4. Back up files and prepare the offline interface.
  5. Connect a wired USB keyboard and mouse.
  6. Disconnect Ethernet and unnecessary peripherals.
  7. Inventory Wi-Fi, Bluetooth and other radios.
  8. Disable or physically isolate communication hardware as appropriate.
  9. Record the actual network isolation configuration.
  10. Boot and display the HPAOC2016 interface locally.
  11. Test View, Sort by, Q–P and >> controls.
  12. Restart and confirm continued offline operation.
  13. Record findings, exceptions and evidence.
  14. Store the completed record in QuantyGRC.

4. Acceptance Criteria

IDPass condition
MON-001Professional monitor clearance
MON-002Ventilation clearance maintained
VID-001Local image display succeeds
INP-001Local interface controls operate
NET-001Ethernet physically disconnected
RF-001Radio isolation documented
OFF-001Offline operation demonstrated
DOC-001Evidence and exceptions recorded

5. Test Report

Status: Not tested. Record technician clearance, network isolation findings, interface results, evidence references, operator and test date.

6. Limits of Claims

A successful demonstration would provide preliminary evidence limited to the tested configuration. It would not establish immunity from cyberattacks, electromagnetic interception or physical compromise.

Electromagnetic information leakage is outside this test's scope and may be evaluated separately under HPAOC2016-EM-001.